OPTIMIZING THE DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY METHOD WITH A HANGING MERCURY ELECTRODE FOR THALLIUM (I) DETERMINATION IN THE PRESENCE OF LEAD (II) AND COPPER (II) FOR APPLICATION IN CONTAMINATED SOILS

Contenido principal del artículo

Yusniel Cruz-Hernández
Mario Villalobos
José Luz González-Chavez
Nadia Martínez-Villegas

Resumen

The conditions that allow thallium (I) determination in the presence of lead (II) and copper (II) were optimized without prior separation of these cations, using a previously developed differential pulse anodic stripping voltammetry (DPASV) method, with a hanging mercury drop working electrode (HMDE) and a Ag/AgCl reference electrode. Unfortunately, the electrochemical activity of lead (II) interferes with this determination, but the addition of 0.1 M EDTA complexing agent (at pH = 4.6) causes a shift in the Pb(II) peak to more negative values, making it possible to quantify Tl(I) in its presence at an optimal deposition potential of –0.550 V. However, the Cu(II) reduction peak, which is normally found far away from that of Tl(I), is also shifted when complexed with EDTA, approaching the Tl(I) peak and becoming an interfering ion. The deposition time and scan rate that were found optimal for the determination were 30 s and 10 mV/s, respectively. Under these conditions it was found that maximum concentration ratios for Pb(II)/Tl(I) and Cu(II)/Tl(I) of 2000 and 400, respectively, did not show interference thus duplicating and quadruplicating the concentrations of Pb(II) and Cu(II), respectively above which interference with Tl(I) occurs, as compared to the standard method published. The proposed methodology has a detection limit of 2 μg/L, a quantification limit of 7 μg/L, and a linear range between 2.3 and
20 μg/L. Enriched Tl solutions of 0.5, 2.5 and 9 μg/L showed excellent recoveries. The methodology was applied to extractions of contaminated soil samples with Tl contents from 0.05 to 3.2 mg/kg.

Descargas

Los datos de descargas todavía no están disponibles.

Detalles del artículo

Biografía del autor/a

Yusniel Cruz-Hernández, Universidad Nacional Autónoma de México

Estudiante de Doctorado en Ciencias de la Tierra, Laboratorio de Geoquímica Ambiental, Insituto de Geologia, UNAM

Mario Villalobos, Universidad Nacional Autónoma de México

Investigador Titular C.

Laboratorio de Geoquímica Ambiental, Instituto de Geología, Universidad Nacional Autónoma de México, Ciudad Universitaria, 04510, Ciudad de México, México

José Luz González-Chavez, Universidad Nacional Autónoma de México

Profesor-Investigador.

Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Ciudad Universitaria, 04510, Ciudad de México, México.

Nadia Martínez-Villegas, Instituto Potosino de Investigación Científica y Tecnológica.

Investigador Titular A.

Instituto Potosino de Investigación Científica y Tecnológica, División de Geociencias, 78216 San Luis Potosí, México.

Compartir en:

PLUMX metrics